Triple walled horizontal autoclave with steam jacket, 75 to 552 L, in a Classic or all SS 304 Prime build, with self-locking radial lock door, a separate SS boiler and a choice of three automatic cycle controllers. 440 V. For laboratory use only.
Cat. no.CapacityBuildController
HTN-AV16175 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV16275 LPrime (All SS 304)LED (standard)
HTN-AV163138 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV164138 LPrime (All SS 304)LED (standard)
HTN-AV161-G75 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV161-R75 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV162-G75 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV162-R75 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV163-G138 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV163-R138 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV164-G138 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV164-R138 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV165175 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV165-G175 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV165-R175 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV166175 LPrime (All SS 304)LED (standard)
HTN-AV166-G175 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV166-R175 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV167185 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV167-G185 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV167-R185 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV168185 LPrime (All SS 304)LED (standard)
HTN-AV168-G185 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV168-R185 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV169235 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV169-G235 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV169-R235 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV170235 LPrime (All SS 304)LED (standard)
HTN-AV170-G235 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV170-R235 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV179339 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV179-G339 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV179-R339 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV180339 LPrime (All SS 304)LED (standard)
HTN-AV180-G339 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV180-R339 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV193552 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV193-G552 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV193-R552 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV194552 LPrime (All SS 304)LED (standard)
HTN-AV194-G552 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV194-R552 LPrime (All SS 304)Recording (21 CFR software)
Non-returnable
Capacity
Choose Capacity
Build
Choose Build
Controller
Choose Controller
Downloads
Product Details
Specifications
Product Details
Product Details
Specifications
Specifications
Performance
  • Pressure
    Adjustable 10 to 20 psi; hydraulically tested to 40 psi
  • Temperature control
    Automatic cycle controller in three versions: LED, graphic LCD with F0 value, and recording with PC reports
General
  • Inner chamber
    SS 304
  • Insulation
    Glass wool between outer chamber and steam jacket
  • Door
    Thick stainless steel radial locking lid; self-locking safety door that cannot open under pressure
  • Safety
    Safety valve, vacuum breaker, pressure control switch, low water cut-off and mains MCB
  • Supplied with
    Boiler with water level indicator and pressure gauge; moisture trap on chamber discharge; separate valves for chamber and jacket
  • Power
    440 V, 3 phase
  • Outer body
    Classic: SS 202 on black powder coated MS stand. Prime: all SS 304, stand included
  • Construction
    Triple walled with steam jacket and separate boiler; argon arc welded
Newsletter

Product updates from Hintron

New instruments, application notes and calibration tips for laboratories, by e-mail. Unsubscribe anytime.

We send a confirmation e-mail first. See Privacy policy.

Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
Added to cart
Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.