0
0
HTN-AV389 high pressure triple walled horizontal autoclave, Classic build, LED controller
HTN-AV389 high pressure triple walled horizontal autoclave, Classic build, LED controller
HTN-AV389 high pressure triple walled horizontal autoclave, Classic build, Graphic LCD controller
HTN-AV389 high pressure triple walled horizontal autoclave, Classic build, Recording controller
HTN-AV389 high pressure triple walled horizontal autoclave, Prime build, LED controller
HTN-AV389 high pressure triple walled horizontal autoclave, Prime build, Graphic LCD controller
HTN-AV389 high pressure triple walled horizontal autoclave, Prime build, Recording controller
High pressure, triple walled horizontal autoclave with steam jacket, 75 to 339 L, 134 °C at 30 psi or 121 °C, in a Classic or all SS 304 Prime build, with self-locking radial lock door, a separate SS boiler and a choice of three automatic cycle controllers. 440 V. For laboratory use only.

Used in:

Measures:

Cat. no.CapacityBuildController
HTN-AV38975 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV389-G75 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV389-R75 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV39075 LPrime (All SS 304)LED (standard)
HTN-AV390-G75 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV390-R75 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV391138 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV391-G138 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV391-R138 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV392138 LPrime (All SS 304)LED (standard)
HTN-AV392-G138 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV392-R138 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV393175 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV393-G175 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV393-R175 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV394175 LPrime (All SS 304)LED (standard)
HTN-AV394-G175 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV394-R175 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV395185 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV395-G185 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV395-R185 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV396185 LPrime (All SS 304)LED (standard)
HTN-AV396-G185 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV396-R185 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV397235 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV397-G235 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV397-R235 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV398235 LPrime (All SS 304)LED (standard)
HTN-AV398-G235 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV398-R235 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV399339 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV399-G339 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV399-R339 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV400339 LPrime (All SS 304)LED (standard)
HTN-AV400-G339 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV400-R339 LPrime (All SS 304)Recording (21 CFR software)
Non-returnable
Capacity
Choose Capacity
Build
Choose Build
Controller
Choose Controller
Downloads
Product Details
Specifications
Product Details
Product Details
Specifications
Specifications
Performance
  • Pressure
    15 to 30 psi working (1.05 to 2.1 kgf/cm²); hydraulically tested to 2.5 times working pressure
  • Temperature control
    Automatic cycle controller in three versions: LED, graphic LCD with F0 value, and recording with PC reports
  • Temperature range
    121 °C and 134 °C cycles, 134 °C max.
General
  • Inner chamber
    SS 304
  • Insulation
    Glass wool between outer chamber and steam jacket
  • Door
    Thick stainless steel radial locking lid; self-locking safety door that cannot open under pressure
  • Safety
    Automatic pressure control, spring loaded safety valves on boiler and chamber, dead weight release valve, automatic low water cut-off, self-locking door, vacuum breaker
  • Supplied with
    Boiler with water level indicator and pressure gauge; moisture trap on chamber discharge; separate valves for chamber and jacket
  • Power
    440 V, 3 phase
  • Outer body
    Classic: SS 202 on black powder coated MS stand. Prime: all SS 304, stand included
  • Construction
    Triple walled with steam jacket and separate boiler; argon arc welded
Newsletter

Product updates from Hintron

New instruments, application notes and calibration tips for laboratories, by e-mail. Unsubscribe anytime.

We send a confirmation e-mail first. See Privacy policy.

Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
Added to cart
Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.