Double walled horizontal autoclave, 75 to 552 L, in a Classic or all SS 304 Prime build, with radial lock lid, a separate SS boiler, pressure control switch and a choice of three automatic cycle controllers. For laboratory use only.
Cat. no.CapacityBuildController
HTN-AV13175 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV131-G75 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV131-R75 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV13275 LPrime (All SS 304)LED (standard)
HTN-AV132-G75 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV132-R75 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV137138 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV137-G138 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV137-R138 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV138138 LPrime (All SS 304)LED (standard)
HTN-AV138-G138 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV138-R138 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV133175 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV133-G175 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV133-R175 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV134175 LPrime (All SS 304)LED (standard)
HTN-AV134-G175 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV134-R175 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV135185 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV135-G185 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV135-R185 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV136185 LPrime (All SS 304)LED (standard)
HTN-AV136-G185 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV136-R185 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV139235 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV139-G235 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV139-R235 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV140235 LPrime (All SS 304)LED (standard)
HTN-AV140-G235 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV140-R235 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV141339 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV141-G339 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV141-R339 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV142339 LPrime (All SS 304)LED (standard)
HTN-AV142-G339 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV142-R339 LPrime (All SS 304)Recording (21 CFR software)
HTN-AV143552 LClassic (SS 304 inside, SS 202 outside)LED (standard)
HTN-AV143-G552 LClassic (SS 304 inside, SS 202 outside)Graphic LCD (F0 value)
HTN-AV143-R552 LClassic (SS 304 inside, SS 202 outside)Recording (21 CFR software)
HTN-AV144552 LPrime (All SS 304)LED (standard)
HTN-AV144-G552 LPrime (All SS 304)Graphic LCD (F0 value)
HTN-AV144-R552 LPrime (All SS 304)Recording (21 CFR software)
Non-returnable
Capacity
Choose Capacity
Build
Choose Build
Controller
Choose Controller
Downloads
Product Details
Specifications
Product Details
Product Details
Specifications
Specifications
Performance
  • Pressure
    Adjustable 10 to 20 psi; hydraulically tested to 40 psi
  • Temperature control
    Automatic cycle controller in three versions: LED, graphic LCD with F0 value, and recording with PC reports
General
  • Inner chamber
    SS 304
  • Door
    Stainless steel plate lid with radial locking; no steam jacket
  • Safety
    Safety valve, vacuum breaker, pressure control switch, low water cut-off and mains MCB
  • Supplied with
    Separate SS boiler, pressure gauge, steam inject and release valves
  • Outer body
    Classic: SS 202 on black powder coated MS stand. Prime: all SS 304, stand included
Newsletter

Product updates from Hintron

New instruments, application notes and calibration tips for laboratories, by e-mail. Unsubscribe anytime.

We send a confirmation e-mail first. See Privacy policy.

Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
Added to cart
Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.