0
0
  1. Home
  2. Flame Photometers
  3. Flame photometer guide
Guide · Flame photometry

Flame photometer: principle, parts and uses

A flame photometer measures sodium, potassium, lithium, calcium and barium. It sprays the sample into a flame and measures the light each element gives off. It is quick, simple to run and cheap to operate, which is why soil, water, cement, food and teaching labs use it every day.

Measures
Na, K, Li, Ca, Ba
Method
Flame emission
Typical range
Na 0–200, K 0–10 meq/l
Hintron models
3
Principle

How a flame photometer works

01

Into the flame

Compressed air draws the sample up and sprays it as a fine mist. In the mixing chamber the mist meets the fuel gas, and the mixture burns at the burner.

02

Atoms form

The flame dries the droplets and breaks the salts into free atoms.

03

Atoms get excited

The heat lifts some of the atoms’ electrons to a higher energy level.

04

Light is given off

As the electrons fall back, each element gives off light at its own wavelength. Sodium, for example, glows yellow at 589 nm.

05

The reading

A filter passes only that element’s wavelength, and a photodetector measures how bright the light is.

06

More element, more light

Over the working range, brightness rises in step with concentration. The instrument is calibrated with standard solutions and the sample is read against them.

Diagram

Flame photometer diagram

Flame photometer diagram: sample, air compressor and nebuliser, mixing chamber with LPG inlet, burner and flame, lens, optical filter, photodetector and display.How a flame photometer worksAir sprays the sample into a mist, LPG joins it in the mixing chamber, and the flame makes each element glow. The filter picks one; the detector measures it.Sampledrawn upAir compressoroil-free, with regulatorairNebulisermistMixingchamberFuel gas (LPG)via regulator and fuel valvefuel inBurnermist + air + LPGFlameatoms excited, then emit lightLensOptical filterone per elementPhoto-detector85meq/lAmplifier anddisplayFilter wavelengthsNa589 nmyellowK766 nmvioletLi670 nmredCa622 nmorangeBa554 nmgreenCa is read on its CaOH band at 622 nm.© Hintron · hintron.com
Parts

Parts and what each does

PartWhat it does
Air compressorSupplies clean air at a steady pressure. Hintron models come with an oil-free compressor fitted with a pressure regulator.
NebuliserCompressed air draws the sample up a fine capillary and sprays it as a fine mist.
Mixing chamberThe fuel gas (LPG) joins the mist and air here. Large drops drain away, so only a fine, even mist reaches the burner.
Burner and flameGives a steady flame of constant shape and temperature. A steady flame means steady readings.
LensGathers the light from the flame.
Optical filterPasses only the wavelength of the element being measured. Na and K filters come as standard; Ca, Li and Ba filters are options.
PhotodetectorTurns the light into an electrical signal.
Amplifier and displayShows the result in meq/l or ppm.
SafetyFlame-failure detection and gas cut-off. Auto-ignition and gas cut-off are on the microprocessor model.
Elements

Elements and wavelengths

ElementWavelengthFlame colourTypical use
Sodium (Na)589 nmYellowWater, soil, food, research samples
Potassium (K)766 nmVioletFertiliser, soil, plant tissue, water
Lithium (Li)670 nmRedLithium salts and ores; internal standard
Calcium (Ca)622 nm (CaOH band)OrangeCement, water hardness, soil
Barium (Ba)554 nmGreenIndustrial and research work
Uses

Where flame photometers are used

FieldWhat is measured
Research and teachingSodium, potassium and lithium in prepared samples and standards; a standard instrument in chemistry and biochemistry practical labs
Soil and agricultureExchangeable potassium and sodium in soil; potassium in fertilisers and plant tissue
WaterSodium and potassium in drinking, boiler and process water
Cement and glassSodium, potassium and calcium (alkali content)
Food and beveragesSodium and potassium in foods, juices and soft drinks
Compare

Flame photometer vs AAS

Both instruments use a flame to turn the sample into atoms. The difference is what they measure: a flame photometer measures the light the excited atoms give off (emission); an atomic absorption spectrophotometer (AAS) measures the light that ground-state atoms absorb from a lamp made for that element (absorption).

Flame photometerAAS
What is measuredLight emitted by excited atomsLight absorbed by ground-state atoms
Light sourceNone: the flame is the sourceA hollow cathode lamp for each element
Wavelength selectionOptical filterMonochromator
FlameFuel gas and air, coolerUsually air-acetylene (about 2300 °C); nitrous oxide-acetylene for some elements
ElementsMainly Na, K, Li, Ca, Ba (easily excited)Most metals: about 60 or more elements
Typical levelppm to tens of ppm, or meq/lLow ppm to ppb (lower with a graphite furnace)
Several elements at onceYes, on dual-channel and multi-element modelsUsually one at a time, with a lamp change for each
Running costLow: fuel gas and airHigher: acetylene, lamps and more upkeep
Skill neededBasicTrained operator
InterferencesFlame temperature, ionisation, spectral overlapChemical and background interference; needs background correction
Instrument costLowMany times higher
Best forRoutine Na, K, Li and Ca at soil, water and food levelsTrace metals such as Pb, Cd, Cu, Zn, Fe and Ni, and regulatory testing

Choose a flame photometer if you only need Na, K, Li or Ca at the usual levels: it is faster, cheaper and simpler.

Choose AAS if you need heavy or trace metals, or limits below the ppm range.

Many labs keep both: the flame photometer handles the daily Na and K work, and AAS handles the trace metals.

Models

Single channel, dual channel or microprocessor?

Single channel (HTN-FL001)Dual channel (HTN-FL002)Microprocessor (HTN-FL003)
Elements per aspiration12 (Na and K together)5
DisplayDual 2½-digit red LEDDual 2½-digit red LED5-digit red LED
RangesNa 0–200 meq/l; K 0–10 meq/l (0–100 optional); Ca 0–10 and Li 0–2 meq/l (optional)Same as single channelSensitivity 0.5 ppm; three-point calibration
Extras——Auto-ignition, gas cut-off, flame-failure detection, memory, optional built-in thermal printer
Best forTeaching labs, low sample loadsRoutine Na and K in soil, water and food labsBusy labs, several elements, records
Method

Getting good results

01

Let it settle

Let the flame settle for a few minutes after lighting.

02

Calibrate

Use fresh standards that bracket your samples.

03

Rinse

Aspirate distilled water between samples.

04

Stay in range

Dilute samples to stay inside the working range.

05

Keep it clean

Keep the nebuliser and capillary clean; use the cleaning wire if the reading drifts.

06

Same settings

Use the same flame setting for the standards and the samples.

Price

What decides the price

The number of channels (single, dual or multi-element), the display and controls (digital or microprocessor), auto-ignition and safety features, the optional Ca, Li and Ba filters, and a printer.

For a quotation, tell us the elements you need, the ranges, and your sample type and load.

Questions

Frequently asked

What is the principle of a flame photometer?

Atoms in a flame are excited by heat and give off light at their own wavelength. The brightness of that light is in proportion to the concentration of the element.

Which elements can a flame photometer measure?

Sodium, potassium, lithium, calcium and barium, the elements that a flame excites easily.

What is the difference between a flame photometer and AAS?

A flame photometer measures the light given off by excited atoms. AAS measures the light absorbed by ground-state atoms from a lamp for each element. AAS covers many more metals at lower levels, but costs much more to buy and run.

Why is calcium read at 622 nm?

In the flame, calcium forms CaOH, which gives a strong orange band at 622 nm that the filter can isolate.

Single or dual channel?

Single channel reads one element per aspiration. Dual channel reads Na and K together, which saves time when you need both.

Request a quotation

Which flame photometer fits your lab?

Tell us the elements, ranges and sample load. We will recommend the right model and send a detailed quotation.

+91 74049 62433
Opens WhatsApp with these details filled in.
Newsletter

Product updates from Hintron

New instruments, application notes and calibration tips for laboratories, by e-mail. Unsubscribe anytime.

We send a confirmation e-mail first. See Privacy policy.

Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
Added to cart
Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.