Hintron HTN-CN007 microprocessor conductivity, TDS, salinity and temperature meter
Benchtop microprocessor meter that reads conductivity, TDS, salinity and temperature, showing temperature together with the chosen parameter on a 16 × 2 backlit LCD. Conductivity runs from 0 to 1000 mS/cm in six automatically selected ranges with 0.1 µS/cm resolution and ±0.5 % of range accuracy; TDS reads up to 200 ppt and salinity up to 50 ppt. Temperature compensation is automatic with the Pt-100 probe, with an adjustable temperature coefficient. Stores 1000 readings with date and time and prints them or sends them over RS-232. Intended for industrial and laboratory use only, not for clinical use.
Non-returnable
Downloads
Application Industry
PharmaceuticalWater and environmentFood, dairy and beveragesEducation and researchAgriculture and soil
Parameters Measured
ConductivityTDSSalinityTemperature
Product Details
Specifications
Product Details
Product Details
Specifications
Specifications
Measurement
  • Calibration
    Cell constant by value, or by measurement in a standard solution · TDS factor set by keys · Salinity factor set by keys · Temperature 2-point against a temperature calibrator (set at the factory)
  • Range
    0 to 1000 mS/cm in 6 ranges · 0 to 200 ppt in 5 ranges · 0 to 50.0 ppt · −20.0 to +200.0 °C
  • Range selection
    Automatic: 0 to 20 µS/cm, 20 to 200 µS/cm, 0.2 to 2 mS/cm, 2 to 20 mS/cm, 20 to 200 mS/cm, 200 to 1000 mS/cm · Automatic: 0 to 20 ppm, 0 to 200 ppm, 0 to 2 ppt, 0 to 20 ppt, 0 to 200 ppt · — · —
  • Resolution
    0.1 µS/cm · 0.1 ppm · 0.1 ppt · 0.1 °C
  • Accuracy
    ±0.5 % of range ±1 digit · ±1 % of range ±1 digit · ±0.5 % of range ±1 digit · ±0.2 %
  • Temperature compensation
    Automatic with the Pt-100 probe for samples from 0 to 70 °C, or a manual temperature set by keys when the probe is not connected
  • Temperature coefficient
    Adjustable, 0 to 4 % per °C (2.00 % by default), referred to 25 °C or 20 °C
  • Input
    Conductivity cell (supplied) · Same cell · Same cell · Pt-100 probe on a 3-pin socket (supplied)
  • Cell constant
    Adjustable: enter the known value, or let the meter measure it in a standard solution
  • Conversion factor
    — · 0.50 by default, adjustable · 0.75 by default, adjustable · —
General
  • Form factor
    Benchtop
  • Display
    16 × 2 alphanumeric backlit LCD
  • Power
    230 V ±10 % AC, 50 Hz
Data and connectivity
  • Display format
    Temperature with conductivity, TDS or salinity, together on the two lines
  • Keypad
    6 soft-touch membrane keys (STORE, PRG, INC, DEC, ENT, ESC) plus ON/OFF
  • Memory
    1000 readings, each with date and time; recall on the display or clear from the menu
  • Clock
    Real-time clock, 24-hour, with date
  • Interface
    RS-232 serial (9-pin) and Centronics parallel (25-pin), for a printer or a computer
  • Serial settings
    1200, 2400, 4800 or 9600 baud; 8 data bits, no parity, 1 stop bit
  • Printing
    All stored readings, or the readings of a chosen date
  • Error indication
    T-ERROR when the sample is below 0 °C or above 70 °C; CAL ERROR / RECAL when the low and high calibration temperatures are less than 20 °C apart; FUL when the memory is full
Newsletter

Product updates from Hintron

New instruments, application notes and calibration tips for laboratories, by e-mail. Unsubscribe anytime.

We send a confirmation e-mail first. See Privacy policy.

Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
Added to cart
Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.