A fully automatic double walled vertical autoclave that sterilizes media, glassware and instruments with steam at up to 20 psi. The inner boiler is 18 SWG SS 304, air insulated from the outer shell, and every unit is hydraulically tested to 40 psi.
Choose in three steps: the size (22 to 180 L), the build, and the controller. Classic is SS 304 inside and SS 202 outside, with black powder coated mild steel legs and radial lock ring. Prime is all SS 304, legs and ring included.
For laboratory use only.
Features
- Six sizes from 22 to 180 L
- 18 SWG SS 304 inner boiler, air insulated; joints laser welded and polished, crevice free
- Works up to 20 psi, hydraulically tested to 40 psi
- Thick machined SS lid with radial locking and jointless gasket
- Automatic cycle: air purged at heat up, timer starts at set temperature, buzzer at the end
- Double safety valve, vacuum breaker, pressure gauge and mains MCB
- Pressure control switch cuts the heater if pressure rises too high
- Cycle stops itself on low water, over-temperature or sensor fault
- Water level indicator, drain valve and SS basket supplied
How the cycle runs

- Heat up: air is let out of the chamber.
- Sterilize: the timer runs at the set temperature.
- Cool down: a buzzer sounds, the heater stops and the pressure falls.
All three controllers run this cycle by themselves. The timer starts only at the set temperature, so every load gets its full time. The cycle stops if the water runs low or the temperature goes too high, and the pressure control switch cuts the heater if the pressure rises too high.
Compare controllers
| Feature | LED | Graphic LCD | Recording |
|---|---|---|---|
| Runs the full cycle automatically | ✓ | ✓ | ✓ |
| Temperature and pressure display | ✓ | ✓ | ✓ |
| Stage and time left on one screen | – | ✓ | ✓ |
| F0 value: how much sterilizing each load received | – | ✓ | ✓ |
| Choose when the cycle ends: as soon as sterilizing time is over, once the temperature has fallen by a set amount, or after a set cooling time | – | ✓ | ✓ |
| Four sensors map the load | – | – | ✓ |
| PC report software built for 21 CFR compliance | – | – | ✓ |
| Batch records and reports on a PC | – | – | ✓ |
| Printer for a paper record (option) | – | – | ✓ |
Why upgrade?
- Graphic LCD: see the whole cycle at a glance. The F0 value adds up the sterilizing effect of every minute above 100 °C, heat up and cool down included, so you can see how much each load received.
- Recording: every batch is recorded and reported on a PC with software built for 21 CFR compliance, which supports audits and validation. Four sensors check the load itself, not just the chamber.
What is the F0 value?
- What: the sterilizing effect of a cycle, counted in minutes at 121 °C.
- How: the controller reads the chamber temperature all through the cycle. A minute at 121 °C counts as 1, at 111 °C as 0.1, at 131 °C as 10. It adds them up, heat up and cool down included.
- Why: the same timer setting can give a big or slow-heating load less sterilizing than a small one. F0 shows what each load actually got.
- Reading it: F0 15 means the same effect as 15 minutes at 121 °C. If a load ends below the F0 your method needs, run it again or check the load.
Please note: F0 shows how much sterilizing a load received, not whether it is sterile. Only biological indicators placed in the load can confirm that.
Sizes
| Capacity | Chamber (dia. × height) | Heater load | Classic Cat. no. | Prime Cat. no. |
|---|---|---|---|---|
| 22 L | 250 × 450 mm | 2 kW | HTN-AV101 | HTN-AV102 |
| 40 L | 300 × 500 mm | 2 kW | HTN-AV103 | HTN-AV104 |
| 50 L | 350 × 550 mm | 3 kW | HTN-AV105 | HTN-AV106 |
| 78 L | 400 × 600 mm | 4 kW | HTN-AV107 | HTN-AV108 |
| 98 L | 450 × 600 mm | 4 kW | HTN-AV109 | HTN-AV110 |
| 180 L | 550 × 750 mm | 6 kW | HTN-AV111 | HTN-AV112 |
Add -G for the Graphic LCD or -R for the Recording controller, for example HTN-AV101-G.
Optional accessories
- Spare gasket
- Dressing bins in various sizes
Performance
- PressureWorks up to 20 psi; hydraulically tested to 40 psi
- HeatingImmersion type heating element
- Temperature controlAutomatic cycle controller in three versions: LED, graphic LCD with F0 value, and recording with PC reports
General
- Inner chamber18 SWG SS 304 sheet, laser welded and polished joints
- InsulationAir insulation between boiler and outer shell
- DoorThick machined SS lid with jointless neoprene rubber gasket
- SafetyDouble safety valve, vacuum breaker, pressure control switch and mains MCB; the cycle stops itself on low water and on over-temperature
- Supplied withPressure gauge, water level indicator, air/steam release cock, drain valve, SS basket
- Power220/230 V AC
- Outer bodyClassic: SS 202 with black powder coated MS legs and radial lock ring. Prime: all SS 304
- Lid lockingRadial lock