Product Categories
 
» Biology
 
Bio Products
Microscopes
Microscope Cameras
Fibre Glass Models
Microtomes
Slides
» Charts
 
2D
3D
» Chemistry
 
Centrifuge Machines
Chemicals
Chemistry general laboratory ware
Crucibles
Cuvettes
Glassware
Plastic ware
Porcelain Silica & Agate ware
Safety Products
Temperature control Equipments
Laboratory Taps
Surgical Taps
Vacuum Pumps
Electronic Analytical Instruments
Thermo & Hygrometers
» Classroom & Office Assecories
 
Classroom & Office Assecories
» Geography
 
Astronomical models
Geology
Glob
» Hospital Furniture & Hollow Ware
» Overhead Projectors
» Physics
» Platinum Lab Ware
» Mathematics's Lab Ware
» Rubber & Silica Ware
» Solders
 
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
61                          

DUAL SCALE AMMETER D.C. with stand
Accuracy 2% on fsd.
Ranges          Range 
HIC 6000 (B) 0 to 2.5A       0 to 5A
HIC 6000 (C) 0 to 1A           0 to 5A
HIC 6000 (D) 0 to 5A           0 to 10A
HIC 6000 (E) 0 to .5A          0 to 1A
HIC 6000 (F) 0 to 3A           0 to 15A


AMMETER D.C. with stand
Acc uracy 2% on fsd.
Ranges
HIC 6000 (H) 0-3 A
HIC 6000 (I) 0-5 A
HIC 6000 (J) 0-10 A
HIC 6000 (G) Galvanometer

30-0-30 divisions 
  Accuracy 1.5% on fsd.
HIC 6000 DC REGULATED POWER SUPPLES. 
  (Single channel continuously variable DC Regulated power supplies)
Input voltage : 230 V+ 10% AC, 50 Hz
Load Regulation : 0.2%
Line Regulation : 0.05%
Ripple : Less than 3mV R.MS
Protection : Against short circuit and over load.
Meters : Two Analog meters.
AVAILABLE IN 0-15 V/2.0AMPS.  TO  0-500V/100mA.
(TEN  MODELS  available  IN DIFFERENT VOLTS AND AMPERES)
HIC 6001 SINGLE CHANNEL CONTINUOUSLY VARIABLE (ECONOMY SERIES)
HIC 6001(A) DC Regulated Power Supply 0-15VDC/1 Amps with one 72mm deluxe quality Acrylic Square meter
HIC 6001 (B) DC Regulated Power Supply 0-15VDC/2 Amps with one 72mm deluxe  quality Acrylic Square meter.
HIC 6002 High Tension AC/DC Power Supply
  H.T. Output Voltage : 0-500V AC/DC,
OutputCurrent : 500mA
L.T. Voltage : 2.5V,4.4V,6.3V & 12.6V AC/2 Amps.
Bias Voltage : 0-100 V DC/10mA
With 2 Deluxe meters to measure  H.T.Voltage & Bias voltage.
HIC 6003 BATTERY ELIMINATORS
Output Voltage/Current
HIC 6003 (A) 2-6 V DC/1 Amps.
HIC 6003 (B) 2-6V DC/2 Amps.
HIC 6003 (C) 2-6V DC/3 Amps.
HIC 6003 (D) 2-12V DC/1 Amps.
HIC 6003 (E) 2-12V DC/2 Amps.
HIC 6003 (F) 2-12V DC/3 Amps.
HIC 6003 (G) 2-12V DC/4 Amps.
HIC 6003 (H) 2-12V DC/5 Amps.
HIC 6004 STEP DOWN TRANSFORMERS
  All Step Down Transformers have AC Output Voltage, protected with fast blow fuse & are 220 VAC Operated. However Output Voltage depends on Input Voltage & Load Current. Output Voltage is available on 4mm sockets/terminals & is selectable using Band Switch.
Output Voltage/Current
HIC 6004 (A) 2-12 VAC/1Amps
HIC 6004 (B) 2-12 VAC/2Amps
HIC 6004 (C) 2-12 VAC/3 Amps
HIC 6004 (D) 2-12 VAC/4Amps
HIC 6004 (E) 2-12 VAC/5Amps
HIC 6005 Transistor Characteristics Apparatus with Regulated Power  Supplies
  Objective : Input & Output Characteristics of Common Base PNP & NPN Transistor 
Features   :  Instrument comprises of Two DC Regulated Power Supplies 0-
10VDC/150 mA & 0-1VDC/150mA, Four meters for voltage & current measurement, 
one PNP & one NPN Transistor mounted behind the panel, connections of 
Supplies & Transistors brought out at 4mm Sockets.
HIC 6006 FET Characteristics Apparatus with Regulated Power Supplies
  Objective : To plot static & Transfer Characteristics.
Features : Instrument comprises of Two DC Regulated Power Supplies 0-
15VDC/150mA & 0-5VDC/150mA, three round meters for voltage & current 
measurement, FET brought out at 4mm Sockets.
HIC 6007 Zener Diode Characteristics Apparatus
  (Forward & Reverse V-I Characteristics)
Objective : To study Forward & Reverse V-I Characteristics of Zener Diode.
Features : Instrument comprises of DC Regulated Power Supply 0-15 VDC 
150mA,two round meters for voltage & current measurement, Zener Diodes 
mounted behind the panel, connections of Supplies, Meters & Zener Diode 
brought out at 4mm Sockets.
HIC 6008 Energy Band Gap of PN Junction Diode.
Objective :  To plot Reverse saturation current Vs Temperature in reverse biased 
PN Junction Diode.
Features : Instrument comprises of DC Regulated Power Supply  0-20 VDC /150mA, 
Two round meters for voltage & current measurement, one PN Junction Diode (Ge Type)
 is kept in Oven. With  temperature control knob.
ELECTRONICS(53-61)
POWER SUPPLIES
DC REGULATED POWER SUPPLES
General Specification:-
Input voltage 230 V+ 10% AC, 50 Hz
Load Regulation 0.2%
Line Regulation 0.05%
Ripple Less than 3mV R.MS
Protection Against short circuit and over load.
SINGLE CHANNEL CONTINUOUSLY VARIABLE DC REGULATED POWER SUPPLY


 
Output Voltage/Current With Two Analog Meters With Two 3.5 Digit LED Digital Panel Meters
0-15V/1.0 Amps
HIC 5999.1
HIC 5999.15
0-15V/2.0 Amps
HIC 5999.2
HIC 5999.16
0-30V/1.0 Amps
HIC 5999.3
HIC 5999.17
0-30V/2.0 Amps
HIC 5999.4
HIC 5999.18
0-30V/3.0 Amps
HIC 5999.5
HIC 5999.19
0-30V/5.0 Amps
HIC 5999.6
HIC 5999.20
0-30V/10.0 Amps
HIC 5999.7
HIC 5999.21
0-60V/1.0 Amps
HIC 5999.8
HIC 5999.22
0-60V/2.0 Amps
HIC 5999.9
HIC 5999.23
0-60V/5.0 Amps
HIC 5999.10
HIC 5999.24
0-300V/100 mA
HIC 5999.11
HIC 5999.25
0-300V/500 mA
HIC 5999.12
HIC 5999.26
0-300V/1.0 A
HIC 5999.13
HIC 5999.27
0-500V/100 mA
HIC 5999.14
HIC 5999.28
DUAL CHANNEL CONTINUOUSLY VARIABLE DC REGULATED POWER SUPPLIES
(WITH TRACKING & INDEPENDENT CONTROLS)
Output Voltage/Current With Four Analog Meters With Four 3.5 Digit LED Digital Panel Meters
0-±15V/1.0 Amps
HIC 5999.29
HIC 5999.35
0-±15V/2.0 Amps
HIC 5999.31
HIC 5999.36
0-±30V/1.0 Amps
HIC 5999.32
HIC 5999.37
0-±30V/2.0 Amps
HIC 5999.33
HIC 5999.38
0-±30V/3.0 Amps
HIC 5999.34
HIC 5999.39

HIC 5999.40 MULTI OUTPUT DC REGULATED POWER SUPPLY

Output voltage/ Current 0-30VDC/2 Amp
0-±15VDC/500mA (Tracking Output)
0-5 VDC/5 Amp.
With one 3.5 Digit DigitalPanel meter to measure all voltages & External DC Voltage.

FIXED OUTPUT DC REGULATED POWER SUPPLIES
HIC 5999.41
5 Volts (Settabe from 4.5 to 5.5 VDC), 0-1 Amp
HIC 5999.42 5 Volts (Settabe from 4.5 to 5.5 VDC), 0-2 Amp
HIC 5999.43 12 Volts (Settabe from 11.5 to 15.5 VDC), 0-1 Amp
HIC 5999.44 12 Volts (Settabe from 11.5 to 15.5 VDC), 0-2 Amp
HIC 5999.45 24 Volts (Settabe from 22 to 26 VDC), 0-1 Amp
HIC 5999.46 24 Volts (Settabe from 22 to 26 VDC), 0-2 Amp
HIC 5999.47 Electronic Standard Cell output voltage 1.018 VDC

PROGRAMMABLE DC POWER SUPPLY
HIC 6031 (B) PROGRAMMABLE DC POWER SUPPLY (0 - 36VDC/3Amps)
Features High Stabilized programmable voltage/current/power outputs

Menu operation by front keypad and rotary switch
Large LCD display with backlit 
Output continuously adjustable output
Maximum current / power output presetable
Constant current/voltage/power output mode
Over current, voltage and over power protection
Memory : Store & recall setup data for different applications
Series/parallel connections
Interface to computer
Safety design     
GENERAL PURPOSE CONTINUOUSLY VARIABLE DC REGULATED POWER SUPPLIES
(FOR VALVE EXPERIMENTS)
HIC 5999.48

DC Regulated Power Supply for Electroforsis Appts. (Solid State)

Output Voltage : 0-300VDC/100 mA (With reversing switch to change the polarity at the output terminates), L.T. Voltage : 6.3VAC/2Amps. Complete with 3.5 Digit LED Digital Panel Meters.
HIC 5999.49

DC Regulated Power Supply for Diode/ Triode Valve Characteristics.
H.T. Volatage Current 0-300VDC/30mA
Bias Volatage/Current 0-25VDC/10mA
L.T. Volatage/Current 6.3VAC/1 Amps with three round meters
HIC 5999.50

DC Regulated Power Supply for Diode/ Triode Valve Characteristics
With three 3.5 Digit LED Digital Panel meters.
H.T. Volatage Current 0-300VDC/30mA
Bias Volatage/Current 0-25VDC/10mA
L.T. Volatage/Current 6.3VAC/1 Amps
HIC 5999.51

DC Regulated Power Supply for Diode Valve Characteristics
H.T. Volatage Current 0-300VDC/30mA
L.T. Volatage/Current 6.3VAC/2 Amps continuously variable with two round meters
HIC 5999.52

DC Regulated Power Supply for Diode Valve Characteristics
With three 3.5 Digit LED Digital Panel meters.
H.T. Volatage Current 0-300VDC/30mA
L.T. Volatage/Current 6.3VAC/2 Amps continuously variable
HIC 5999.53

DC Regulated Power Supply for Triode/ Pentode Valve Characteristics Appts.
H.T.1 Volatage Current 0-300VDC/30mA
H.T.2 0-300VDC/30mA
Bias Volatage/Current -25VDC to +25 VDC/10mA
L.T. Volatage/Current 6.3VAC/1 Amps with five round meters
HIC 5999.54

DC Regulated Power Supply for Triode/Pentode Valve Characteristics Appts.
With five 3.5 Digit LED Digital Panel meters.
H.T.1 Volatage Current 0-300VDC/30mA
H.T.2 0-300VDC/30mA
Bias Volatage/Current -25VDC to +25 VDC/10mA
L.T. Volatage/Current 6.3VAC/1 Amps
HIC 5999.55

DC Regulated Power Supply
(General Purpose)
H.T. Volatage Current 0-300VDC/100mA
Bias Volatage/Current 0-100VDC/10mA
L.T. Volatage/Current 6.3VAC/1 Amps with 3 rectangular deluxe meters
HIC 5999.56

DC Regulated Power Supply
(General Purpose)
With three 3.5 Digit LED Digital Panel meters.
H.T. Volatage Current 0-300VDC/100mA
Bias Volatage/Current 0-100VDC/10mA
L.T. Volatage/Current 6.3VAC/1 Amps
HIC 5999.57

DC Regulated Power Supply for Millikan's Oil Drop Apparatus
Output Volatage/Current 0-300VDC/100mA
(With reversing switch to change the polarity at the output terminals)
L.T. Volatage/Current 6.3VAC/1 Amps, with 1 round meter

                                                                                                              
     
     